Wind turbine main gearbox refurbishment

Wind turbine main gearbox refurbishment

 

Project details

Client: Earthmill
Application: Main gearbox bearings, case bores, second – third line gearing line gearing
Gearbox: Schaeffer, helical gearing throughout
Reported Problem: Main gearbox failure
Considerations: Second line bearings were being overloaded leading to damage and ultimate gearbox failure
Brief: Strip and investigate, report, analysis of recovery options, refurbish with existing and new parts, test, paint and dispatch
Results: Refurbishment of worst damage at less than half the cost of a new unit. Combination of OEM gear parts and reverse engineered parts substantially reduced lead time.